Vision panels exceeding 100 square inches in 60 and 90 minute doors require fire resistive glazing.
Vision panel fire door regulations.
Glazed vision panels are often used within door leaves to let light into a room for aesthetic reasons or for safety i e.
Allowing people using the door to be seen vision panels should be towards the leading edge and with vertical dimensions including at least the minimum zones shown either with or without a horizontal rail.
Unless it can be argued otherwise in the access statement e g.
Building regs approved document b requires vision panels in doors so that you can see if there are signs of fire on the other side.
To accommodate an intermediate horizontal rail see diagram 1 above.
Vision side lights if provided 404 2 11 accessible viewing height 43 max.
Regardless if the building is fully sprinklered.
Unless not in tended for viewing i e lowest part above 66 doors doorways and gates 206 5 and 404 compliance is required for doors doorways and gates providing user passage on accessible routes.
The 2012 and 2015 ibc limits the size of ceramics and fire protective glazing used in the door vision panel in 60 90 minute exit stairway or passageways to 100 sq.
Vision panel limitation is by using fire resistive glazing that meets astm e 119.
For reasons of security door leaves and side panels wider than 450mm have vision panels towards the leading edge of the door whose vertical dimensions include at least the minimum zone or zones of visibility between 500mm and 1500mm from the floor if necessary interrupted between 800mm and 1150mm above the floor e g.
The door vision panels for the 90 minute pair doors are allowed to exceed 100 square inches because the door incorporates fire resistive glazing that meets astm e 119.
At least one accessible door.